The requirement of a good earth resistance is extremely important with the installation of any earthing system.
LPI’s RESLO provides the ability to dramatically reduce soil resistivity even in soils with average
electrical conductivity.
RESLO is comprised of specifically selected compounds, which possess excellent electrical
conductivity. When RESLO is mixed with water and poured on the earthing system and surrounding soil
the powder and water react to form a hardened mass within your earthing system. RESLO will not wash
away under seasonal conditions and therefore provides a permanent presence in working to improve
and maintain the integrity of your earthing system. Given that RESLO does not wash away the
requirement to re-treat the soil as is the case with other enhancing compounds is eliminated.
RESLO is supplied in multiples of 10kg-packaged bags to suit your site application. These packaged
bags have full installation and handling instructions and combine a plastic handle and HDPE plastic
inner for ease and safety of handling.
· Product Application
Given that all earthing systems are installed in varying soil types and conditions, it must be understood
that the application results of RESLO will also be dependant on these site-specific conditions. For a
typical trench installation, one 10 Kg kit of RESLO will achieve desired earth resistance levels in
combination with appropriate conductors for a trench covering 2.5m in length x 300mm in width and a
depth of 500mm to 1000mm.
All earthing systems are typically required to achieve a Ground DC Resistance of < 10 Ohms and
impedance of < 30 Ohms as outlined in most standards.
If installing either a radial earthing system or grid type earthing system it is recommended that all
earthing conductors be installed at a depth of between 500mm and 750mm (recommended) with a
maximum depth of 1000mm. In order to further assist in improving the earth resistance of the system, it
is recommended that excavated soil of poor quality (Rocky) be replaced with soil of a good quality prior
to replacing the earthing system with all excavated soil